Showing posts with label engine. Show all posts
Showing posts with label engine. Show all posts

Wednesday, July 20, 2011

engine Oil Flow measurement - Which Flowmeter?

One of the most difficult flow measurements for the automotive engineer is to measure the motor oil flow rate under operating conditions. With the motor mounted on a test bench and coupled to a dynamometer, the job is slightly easier due to the increased space availability, but none the less, meticulous option and premise of the flow determination system is required. Flow measurements required in the motor bay of a vehicle come to be additional restricted due to instrument power requirement, premise space required and the harsh under bonnet conditions.

What are the flowmeter options? Well, business standards seem to exist to some extent, but this does not mean they are correct. Let us look at some options.

Clamp Meter

(1) The obvious displacement meter, this could be in the form of a gear meter, piston meter or helical screw to name a few. These meters are generally on the higher cost side and can cause issues when installed due to their relatively high pressure drop. Although quite good at operating across wide viscosities they do suffer from meter slippage at low viscosities. Meters vary in size, but can often be installed without the need for any flow conditioning. Used by some motor test houses but not an ideal solution.

(2) Turbine flow meter, generally one of the most widely used flowmeters for motor oil flow measurement, mainly due to its low costs and small size. They can be purchased relatively undoubtedly from a host of manufacturers and have a manageable pressure drop which is not too detrimental to oil system performance. They are sensitive to oil and fluid flow profile effects, so it is very prominent to calibrate the flow meter across the varying oil viscosity range and with its installed upstream and downstream flow conditioning tubes. To ensure precise results when in use, it is requisite to match the installed conditions as close as possible. Quite often master flow calibration laboratories will calibrate the flow meter on the same motor oil, at the same operating climatic characteristic and with the same inlet and outlet connections as per the installed engine. Sometimes this may be part of the motor assembly, such as an oil cooler or oil filter assembly, generally the easiest part of the motor where the oil flow can be interrupted. Many flow meter manufacturers only supply a calibration certificate on water, which can lead to very large errors if used on motor oils.

(3) Coriolis meters. Very good high accuracy meters, that would only be superior to fixed installations. These meters remain very high-priced and are large in size, compared to the turbine and obvious displacement meters. These meters have progressed well over the last 10 years, but can still be prone to poor installation, vibration and zero drift determination errors. Ideal for test bench use where they are enduringly installed, and with right tube models now becoming a norm, they offer low pressure drop and exquisite viscosity rangeability.

(4) Pressure Drop Characterization. An increasingly coarse recipe for obtaining precise measurements without affecting the oil system carrying out due to insertion of flowmeters. Individual parts of the motor oil flow system are instrumented for pressure tapping locations and each motor part is flow characterized on a calibration bench for oil flow against pressure drop at the required temperatures. Once each system has been characterized the motor is reassembled and tested, and the recorded pressure measurements are then used to obtain the flow rate. This recipe is generally used on requisite motor lubrication surveys, where the insertion of a flow meter would have a detrimental succeed on the oil flow system.

(5) Ultrasonic Clamp on meter. Although a non intrusive device, due to its right pipe premise requirements, it does mean the system becomes intrusive into the oil determination system. Still very high-priced to purchase, and presently not sufficiently tested in these applications to come to be a favorable contender, although progressing faster than most other techniques.

Having decided on your recipe of flow measurement, and undertook the required level of flow meter calibration across the range of operating temperatures, you are close to taking a basal step forward in acquiring good flow determination results. Engineers relatively new to motor lubrication studies should seek advice from the Flow Calibration Laboratory, who should be suitably experienced in this type of flow determination application and be in a good position to find the best clarification for your allocation and flowmeter hardware inventory.

Other Issues to bear in mind. The involved nature of motor oil flow determination means it is very difficult to get precise oil flow readings from a running engine, but the informed engineer can make sound engineering judgements on their determination process. Keep in mind the influences of oil viscosity, oil temperature, meter premise succeed on flowmeter and oil pump performance, oil aeration, relief valve effects and hysteresis, fuel dilution effects, motor oil levels, etc. The next series of discussions will delve deeper into the implications of these parameters in more detail.

engine Oil Flow measurement - Which Flowmeter?

Visit : uk games and toy store to buy video games Store Automobuy Store

Wednesday, March 23, 2011

Troubleshooting Problems With Your Fastback Model 11 Binding engine

If you have a Powis Parker Fastback model 11 binding engine you probably already know how easy it is to use. However, from time to time with any engine problems can arise. This description is designed to supply a quick troubleshooting guide for the Fastback 11 that will supply you with some of the most base problems, their causes and inherent solutions. If you have a problem that is not listed here, you should in fact experience an authorized Fastback dealer and they should be able to either walk you straight through a solution to your problem or set up a aid call to fix your unit.

Problem #1: engine Doesn't Power On
This problem can sometimes occur if there is a problem with A.C. Power. Check to make sure that the Ac power cord is firmly plugged in to the back of the engine and into the wall. Also check to make sure that you have power to the outlet that you are trying to use. It is also inherent that you may have a blown fuse on your machine. If this is the case you will need to replace the fuse before the unit will work.
Problem #2: Can't Insert A Binder Strip
This problem most often occurs when the book clamp is not finished on the machine. Press the bind button to kick off the book clamp and you should then be able to insert your strip.
Problem #3: Left Status Indicator Light Blinks Red And The Bind Clamps Re-Open After The Bind Button Is Pressed
This problem will happen if the document is too thick to be bound with the Model 11. You will need to take off some pages or bind the document in two sections. If you frequently need to bind documents larger than 1 inch thick you may need to reconsider upgrading from the Fastback 11 to the Fastback 15xs.
Problem #4: Document Is Not Bound
This problem can happen if you accidently insert the Binder Strip wrong side up into the machine. If this is the case you will need to clean your engine to take off the adhesive that was deposited onto the heater plate of your unit. This can also occur if you are using a twisted or damaged Fastback Strip. In that case you simply need to retry with a new Binderstrip.
Problem #5: Binderstrip Is Not In Line With The End Of The Document
This can happen if the wrong distance of Binderstrip is used. Check and make sure that the distance of the Binderstrip and the document match. This can happen if you inadvertently bind a document with a damaged Fastback Strip. Try a new strip and see if it works better. This can also happen if there is adhesive buildup on the heater plate of your unit. If this is the case you will need to clean the heater plate.
Problem #6: Binderstrip Is Only Partially Bound To The Document Or Is Severely Askew.
This problem can happen if there is adhesive buildup on the heater plate of the Fastback 11. The adhesive will need to be cleaned off before the unit will operate properly. This problem can also happen if you effort to use a damaged Binderstrip. If there isn't any adhesive buildup on the heating plate or internal strip guide then you may want to try other strip to see if that works.
Problem #7: Binderstrip Is Ejected From The engine And The Right Status Light Is Solid Red.
This problem commonly occurs if a Binderstrip is fed incorrectly or more than one strip is fed at one time. Check to make sure that you aren't trying to feed more than one strip and determined insert a singular strip again.
Problem #8: Right Status Light Is Solid Red And Power Light Is Solid Red
This error commonly means that there is a binderstrip jammed inside your machine. You will need to take off the jammed strip and clean up any adhesive residue before trying to bind other book.
Problem #9: Power Light Is Continuous Red
This is a code that indicated engine malfunction. You should try and turn the power switch of the unit off and then turn it on again. If the problem persists you will need to call your Powis Parker authorized dealer to arrange a aid call.

Clamp Meter

Troubleshooting Problems With Your Fastback Model 11 Binding engine

Thanks To : Motorcycle Store video games Store