Saturday, July 16, 2011

How to Troubleshoot a Hot Tub Heater

I have been asked this question by so many customers. Why won't my hot tub heat up? I have talked habitancy through this process over the phone and have sent them a list of information on how to test the spa heater themselves. I do not usually propose that an end user try to troubleshoot their own spa. Working with electricity can be risky and working with electricity and water can be deadly. It is all the time recommended to contact a mighty aid technician for any troubleshooting. That said, many habitancy are more than capable of troubleshooting their own spa heater and this guide will help them.

Spa & Hot Tub Heater Troubleshooting Guide

Clamp Meter

An easy to effect Spa & Hot Tub heater Troubleshooting Guide. Troubleshooting a spa heater can be a simple course if you have the right tools.

Note: This troubleshooting guide is meant for trained spa aid professionals. It is not recommended for the spa owner to troubleshoot their own spa.

Tools you will need to have are:

A Multimeter, to check voltage, and a Clamp on Amp Meter, to check for amp draw at the element. You can not accurately troubleshoot a Spa heater element without these tools.

Multi-Meter: Used to test for voltage at the heater element terminals.

Amp Meter: Used to check for amp draw by the heater element.

You will also need assorted hand tools. Screw drivers, Pliers, open end wrenches, etc.

Note: Spa must be full of water and in normal operating condition to perform these tests

To test the heater element, you must: Check voltage at heater element

1. Turn Power off to spa. (This means to shut off source voltage to the spa at the breaker or disconnect).
2. Open equipment area and find the heater assembly.
3. Open the spa heater assembly to expose the heater terminals.
4. Make sure all other wires and connections are away from the heater terminals.
5. Open spa filter housing and take off filter. Replace filter lid and obtain for operation.
6. Double check area nearby heater terminals to make sure you have way to the terminals with the multi-meter probes, without the hazard of touching other contacts.
7. Remember, when you re-apply power to spa, you will be working with 240 volts of electricity. Water and electricity do not mix.
8. Make sure no water is near the terminals where you will be working. Also, make sure you are not kneeling or standing in water while testing for voltage at the heater terminals.
9. Re-apply power to spa and turn thermostat up to cause heater to come on. Listen to spa to see if operation sounds normal.
10. Turn multi-meter on and plug probes into the meter as directed by the meter instructions. You will be testing voltage.
11. Carefully place one probe on one of the element terminals.
12. Carefully place the second probe on the other heater terminal.
13. Read your multi-meter for voltage at the element.
14. take off both probes, and write down the voltage you read from your test.
15. Turn power off to spa. If you received "0" volts at the heater terminal, your question is most likely not the heater element. If you received the precise voltage at the heater terminals, you must now check for amp draw at your heater.

Check amp draw at heater element

1. Turn power off to spa. (This means to shut off source voltage to the spa at the breaker or disconnect).
2. Find wires that join together to the spa heater terminals.
3. Clamp one wire that goes to your heater element, with your amp-meter.
4. Make sure all wires are obtain and safe for operation.
5. Re-apply power to your spa and turn thermostat up to cause heater to come on.
6. Check amp-meter to see if amps are being drawn by your heater element.
7. Turn Power off to spa.
8. Write down the amp reading from your amp-meter. If you received an amp reading from your heater. Your heater element is working. You need to look for problems elsewhere.

*I f you received the proper voltage at the heater terminals, but received no amp reading when the spa was operating, the heater element is bad.

What to do if heater element tests good during these tests, but does not heat spa, during normal operation. Remember step 5 in the voltage test. You removed the filter. Check condition of filter, run spa for 24 hrs without filter in place to see if spa heats normally. If spa heats usually with filter out, replace filter with new.

Now be aware every hot tub / spa is different. If you have a digital system, make note of any displayed error codes. The new digital systems on the spas today will do much of the troubleshooting for you if you know what it is telling you, but let's leave that for other record though.

How to Troubleshoot a Hot Tub Heater

Friends Link : rockwell tools blog reviews Motorcycle Store

Wednesday, July 13, 2011

Great Price Fluke Remote Display True-rms AC/DC Clamp Meter With iFlex

Fluke Remote Display True-rms AC/DC Clamp Meter With iFlex Review


Click To Buy Best Price from Amazon

Product Feature

  • FLUKE-381

Product Overview

First clamp meter with a detachable, remote display for easier, faster, safer measurements! Model 381 model with wireless remote display lets you do the jobs that used to take two people. Clamp around a conductor, remove the display and walk across the room (up to 30 ft.) to operate controls or remove protective equipment, all while watching real-time readings. Radio transmitter automatically turns off when the display is connected to the meter. Both models feature large, easy-to-read, backlight display which automatically sets the correct measurement range. The 18" iFlex™ flexible current probe expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward-sized conductors and improved wire access. Includes soft carrying case. Measurement capability: 1000 A ac and dc current measurement with fixed jaw 2500 A ac current measurement with iFlex™ flexible current probe 1000 V ac and dc voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Frequency measurement to 500 Hz with both jaw and iFlex™ 60 kΩ resistance measurement with continuity detection Min, max, average and inrush recording to capture variations automatically 3-Year Warranty

Read More ...



See Also : rockwell tools blog reviews rockwellrk 9000 jawhorse Automobuy Store

Monday, July 11, 2011

Check Out AC Line Splitter for $13.25

AC Line Splitter Review


Click To Buy Best Price from Amazon

Product Feature

  • For Measuring Current in Plug-In Appliances and Air Conditioners
  • Splits Two Conductor Line Cord For Reading at Outlets Under Load
  • Permits Voltage Measurements at Outlet Under Active Conditions
  • Direct and 10X Sensitivity

Product Overview

AC Line Splitter.This instrument is a special accessory for clamp meters which can be used to measure current conveniently without destroying the insulation part of the equipment power line.

Read More ...



Related Products

Visit : uk games and toy store to buy Motorcycle Store

Saturday, July 9, 2011

Great Price Fluke 322 Clamp Meter w/DC Volts

Fluke 322 Clamp Meter w/DC Volts Review


Click To Buy Best Price from Amazon

Product Overview

The Fluke 322 is designed to verify the presence of load current, AC voltage and continuity of circuits, switches, fuses and contacts. These small and rugged clamp meters are ideally suited for current measurements up to 400 A in tight cable compartments. The Fluke 322 also offers DC voltage measurements and has a higher resolution for loads below 40 A.

Read More ...



Thanks To : Motorcycle Store

Wednesday, July 6, 2011

Great Price Fluke 31 Clamp Meter

Fluke 31 Clamp Meter Review


Click To Buy Best Price from Amazon

Product Feature

  • Measures - Current AC
  • Display - LCD and Analog
  • Amps Range AC - 700A (1000A peak)
  • Frequency Range - 10,000Hz
  • Parts Included - Clip-On Holster, 9V Battery

Product Overview

True RMS AC Current, Display Hold, Manual/Auto Ranging

Read More ...



My Links : video games Store uk games and toy store to buy

Saturday, July 2, 2011

Great Price Fluke AC285 SureGrip Alligator Clips

Fluke AC285 SureGrip Alligator Clips Review


Click To Buy Best Price from Amazon

Product Feature

  • For use with TL222 and TL224 test leads
  • Nickel plated steel jaws
  • One pair (red, black)
  • SureGrip accessories are designed to improve steadiness in slippery hands
  • Rubber overmolded surfaces and finger-hugging curves give the user a comfortable, reliable grip

Product Overview

Sure-Grip accessories are designed to improve steadiness in slippery hands. Rubber over molded surfaces and finger-hugging curves give the user a comfortable, reliable grip on the accessory so they can focus on making an accurate measurement.

Read More ...



Related Products

Friends Link : Motorcycle Store rockwellrk 9000 jawhorse